PIO
(Parallel Input / Output) Connection
|
|
Pin No.
|
Signal Name
|
Purpose
|
|
Input
|
1
|
RESET
|
Hardware reset |
2
|
ORIGIN
|
Returning to origin | |
4
|
JMK START
|
Marking J number set in "STROBE4" | |
8
|
REMOTE
|
Changing to Remote Mode externally (with Operating Unit) | |
13
|
STROBE4
|
Sending J number set in "DATA0" to "DATA9" to controller | |
14
|
STROBE5
|
Marking S number set in "DATA0" to "DATA9" | |
15
|
DATA0
|
Binary data area
Connect as many as necessary. (e.g..) When you use J numbers from 1 to 15, you must use "DATA0" to "DATA3". |
|
16
|
DATA1
|
||
17
|
DATA2
|
||
18
|
DATA3
|
||
19
|
DATA4
|
||
20
|
DATA5
|
||
21
|
DATA6
|
||
22
|
DATA7
|
||
23
|
DATA8
|
||
24
|
DATA9
|
||
25
|
IN-COM
|
Supplying 24VDC power (MAX: 2A) | |
Output
|
26
|
REMOTE
|
Signal to indicate that the machine is remote controllable. When the signal is OFF, you cannot control the marking machine via the parallel interface. |
27
|
BUSY
|
Signal to indicate that the machine is operating. When the signal is ON, all input signals except for reset signal will be denied. |
|
*31
|
BATTERY
|
Signal to indicate under boltage of the memory backup battery. | |
*32
|
TEMP
|
Signal to indicate that the temperature is 0 degrees C or lower or 50 degrees C or higher. | |
33
|
SERVO
|
Signal to indicate that the servo amplifier is ready. | |
41
|
ERROR
|
Signal to indicate an error has occurred on the marking machine. | |
50
|
OUT-COM
|
Supplying 24VDC GND (MAX: 2A) |
*
|
You can check the battery condition and temperature with LEDs on the front side
of the controller. |
| Set parameters necessary
for marking beforehand on the controller of the VM7700 series machine. You can set parameters via following items: ・Dedicated Software for Our Marking Machine ・VM7891 Operating Unit ・Input Device prepared by yourself (The device that parameters can be set by RS-232C commands specified by us) (for the specified RS-232C commands, please contact us.) (Note) No parameter settings are required for I/O (Parallel) interface. |